All Categories > Products > AC Motors > General Purpose Motors > Drip-Proof Motors > Leeson Rigid Base Single Phase Drip-Proof Pressure Washer Motors > Item # 116706  
Request Quote

Item # 116706, Leeson Rigid Base Single Phase Drip-Proof Pressure Washer Motors


3 HP, 3450 RPM, NEMA Frame 56H, 230 V
  • Rigid Base
  • Single Phase
  • Drip-Proof
Pressure Washer Pump Motors Low Amperage Design
Motors specially suited for hot or cold pressure washer applications and other single phase installations requiring minimum starting and running amperages. Capacitor start, capacitor run construction for reduced amperage.





Specifications  · Features

Specifications

Base

Rigid Base

Enclosure Type

Drip-Proof

Phase

Single

HP

3

RPM 60 Hz

3450

Voltage

230 V

Overload Protection

Manual

FL Amps 230 V

15.0

NEMA Frame

56H

Disc. Sym.

A

C Dimension

12.38 in

Approx. Weight

39 lbs

Mechanical Features

Double shield ball bearings prelubricated with Exxon POLYREX® EM lubricant, having operating temperature range of -20ºF to +350ºF and special formulation to provide extra long life and moisture resistance. Dynamically balanced rotor and shaft assembly.

Electrical Features

High efficiency reduced amperage energy saving designs. Stator impregnated with extra heavy varnish system. High temperature copper magnet wire for high overload capacity. Capacitor start/capacitor run design for reduced amperage. Grounding provision in conduit box. Manual reset overload protector protects against automatic resets. High overload capacities provided by service factor.

Manufacturer



Features
  • Combination 56H base motors have mounting holes for NEMA 56 and NEMA 143-5T and a standard NEMA 56 face and 5/8" shaft.
  • Capacitor start/capacitor run design for reduced amperage, others are capacitor start/induction run.
  • Class F insulation




    Download PDF Download PDF   