Item # 6KFP53100X9XXXA1, AF-600 FP Fan and Pump Drives - 575V, 3-Phase, 50/60 Hz Input
|
List Price $11,800.00
|
|
|
100 HP, 575 V
|
|
|
|
|
Voltage
|
|
575 V
|
|
Phase
|
|
Three
|
|
Frequency
|
|
50/60 Hz
|
|
HP Rating
|
|
100
|
|
kW Rating
|
|
75
|
|
Rated Output Amps
|
|
100
|
|
Overload Amps (110% 1 Min)
|
|
110
|
|
Standard Unit Includes
|
|
IP20 (9) Chassis Keypad
|
|
Factory Installed Keypad
|
|
Keypad
|
|
Drive Type
|
|
IP20/Open
|
|
A1/B RFI Filter
|
|
No A1/B RFI Filter Installed
|
|
Load Share
|
|
Standard Unit
|
|
Conformal Coating
|
|
No Conformal Coatings
|
|
Revision
|
|
1st Revision
|
|
Option Kits
|
|
NEMA1ACC4, Field Installed IP21/NEMA 1 Add-On Option Kits for AF-650 GP General Purpose Drive ($175.00)
|
|
Options and Accessories
|
|
OPC24VPS, 24V DC External Supply Module ($240.00) OPC4XPED, Pedestal Kit ($875.00) OPCAIO, Analog I/O Module ($500.00) OPCBAC, BacNet Communications Module ($600.00) OPCCOVER4142, Power Shield for Unit Size 41 and 42 Drive ($520.00) OPCCOVER51, Power Shield for Unit Size 51 Drive ($1,305.00) OPCDEV, DeviceNet Communications Module ($600.00) OPCEIP, Ethernet IP Communications Module ($700.00) OPCGPIO, General Purpose I/O Module ($475.00) OPCLON, LonWorks Communications Module ($600.00) OPCMBTCP, Modbus TCP Communications Module ($700.00) OPCPDP, Profibus DP Communications Module ($725.00) OPCPRT, ProfiNet RT Communications Module ($700.00) OPCRLY, Relay Output Module ($475.00) OPCRMKNC, Remote Mounting Kit without cable ($85.00) OPCTERM, Screw Terminal Accessory ($25.00) OPCUSB, USB Kit for All Drives up to Unit Size 5X ($75.00) OPCUSB6X, USB Kit for All Unit Size 6X drive ($225.00) RMKYPDAC, Remote Mounting Kit for Graphical LCD Keypad ($95.00)
|
|
|
|
|
|
|
Approvals
|
|
CE, UL, cUL, and C-Tick Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes for 208/230 V and 460 V.
|
|
|
|
|
Rated Input AC Voltage
|
|
200-240 Vac, 3-phase, 50-60 Hz, ± 10 % V 380-480 Vac, 3-phase, 50-60 Hz, ± 10 % V 525-600 Vac, 3-phase, 50-60 Hz, ± 10 % V
|
|
Max. Voltage Imbalance
|
|
3 % of rated supply voltage
|
|
True Power Factor
|
|
> 0.9 nominal at rated load
|
|
Displacement Power Factor
|
|
> 0.98
|
|
Switching on Input Power Supply
|
|
Maximum twice/minute up to 10 HP, Maximum once/minute above 10 HP
|
|
Environment According to EN60664-1
|
|
Overvoltage category III/pollution degree 2
|
|
DC Link Reactors
|
|
Built-In DC Link Reactors on all ratings
|
|
RFI Filters
|
|
Built-In RFI Filters to reduce noise generated by the drive. Meets industrial standards.
|
|
|
|
|
|
|
|
|
|
|
|
|
Operation Method
|
|
Keypad operation: Hand, Off, Auto Digital Input: Programmable for Start/Stop, Forward/Reverse, Jog Timer operation: Stop after predetermined time frame Communications: RS-485 Modbus RTU, Metasys N2, and Apogee FLN P1 USB Port for programming drive with optional PC Software
|
|
Frequency Reference Signal
|
|
Left or Right Arrow buttons on keypad in Manual Mode Speed Potentiometer: 0 to +10 Vdc, 10 to 0 Vdc 0-10 Vdc analog input 0/4-20 ma analog input
|
|
References
|
|
Up to 3 Input References can be selected from Analog Input #1 or #2, Frequency Input #1 or #2, Network, or Potentiometer
|
|
Digital Input Signal
|
|
No Operation Reset after drive trip or alarm Drive at stop with no holding current Quick Stop according to Quick Stop Decel Time 1 Stop on input going low Start Maintained Start after signal applied for Minimum of 2 ms Reversing Start Reverse Enable Start Forward only Enable Start Reverse only Jog Multi-Step Frequency selection (1 to 8 Steps) Hold Drive Frequency Hold Reference Speed Up; activated by Hold Drive Frequency or Hold Reference Slow Down; activated by Hold Drive Frequency or Hold Reference Drive Parameter Setup Select 1-4 Precise Start or Stop; Activated when drive parameter precise start or stop function is selected Catch Up or Slow Down; Activated by signal to add to or subtract from input reference to control speed Pulse Input selectable from 100-110000 Hz Accel / Decel Time select. Set Input to Accel / Decel Times 1 to 4 Digital Potentiometer Input Increase or Decrease Mechanical Brake Feedback
|
|
|
|
|
Keypad Features
|
|
LCD Display with 6 Alpha-numeric lines. Multi-Language Support Hot Pluggable, Remote Mount Option, and CopyCat Feature, IP65 rating when remote mounted on enclosure LED's - Green - drive is on, Yellow - indicates a warning, Red - indicates an alarm, Amber - Indicates active Menu keys and H-O-A keys
|
|
Keypad Keys
|
|
Status - shows status of drive Quick Menu - Enters Quick Start, Parameter Data Check, or Trending Modes Main Menu - Used for programming all drive parameters Alarm Log - Used to display Alarm list Back - Reverts to previous step or layer in parameter structure Cancel - Used to cancel last change or command Info - Displays information about a command, parameter, or function in any display. Hand/Off/Auto - Used to control drive locally or put drive in remote mode Reset - Used to reset Warnings or Alarms
|
|
Password
|
|
2 Level Password Protection
|
|
Alternate Motor Parameters
|
|
Up to 4 Separate complete parameter set-ups are available
|
|
Graphical Trending
|
|
Trend - Speed, Power, or Frequency
|
|
|
|
|
|
|
All AF-650 GP drives can be mounted Side-by-Side without spacing. For all drives rated 125 HP or below allow 3.4 inches (100 mm) free space above and below. For all drives rated 150 HP and above allow 8.9 inches (225 mm) free space above and below.
|
|
|
|
|
|
|
|
 |
|
|
|
|
|