Koffler Electrical Mechanical Apparatus Repair, Inc
527 Whitney St
San Leandro, CA 94577 USA
Phone: 510-567-0630
Fax: 510-567-0636
Email: info@koffler.com
Website: http://www.koffler.com
|

|
|
|
Item # M7710, GE Energy $aver® TEFC Severe Duty Motors
|
|
|
|
30 HP, 3600 RPM, NEMA Frame 286TS, 230/460 V, TEFCGE Motors has been manufacturing premium efficient motors since the late 1970’s. The latest Energy $aver® design meets EIS Act (Energy Independence & Security Act 2007) efficiency levels (which are based on NEMA Premium® MG1 table 12-12). Other standards and certifications include CSA-Motors and C-390, UL Component & Insulation System Recognition and CE mark for 320 frame and below.
|
|
|
|
|
|
|
Poles
|
|
2 4
|
|
Efficiency
|
|
NEMA Premium
|
|
Frequency
|
|
50 Hz
|
|
NEMA Design
|
|
B
|
|
Agency Approvals
|
|
C-390 - CE mark CSA - Motors UL - Component and Insulation System Recognition
|
|
Altitude
|
|
3300 ft
|
|
Ambient Temperature
|
|
40 ºC
|
|
Balance/Vibration
|
|
0.15 in/sec max
|
|
Bearing Type
|
|
Ball, Sealed
|
|
Conduit Box
|
|
Cast Iron
|
|
End Shield
|
|
Cast Iron
|
|
Fasteners
|
|
Metric
|
|
Frame Material
|
|
Cast Iron
|
|
Grease
|
|
Lithium
|
|
Ground
|
|
Brass Bolt in Conduit Box
|
|
Insulation Class
|
|
Class F
|
|
Insulation System
|
|
GEGARD1800™, Non-Hygroscopic, Anti-Fungus, meets, NEMA MG1-31
|
|
Inverter Capabilities
|
|
Variable Torque 10:1, Constant Torque 4:1
|
|
L10 Bearing Life
|
|
Direct Coupled: 65000 hrs, Belted: 26280 hrs
|
|
Lifting Means
|
|
Eye Bolt
|
|
Mounting
|
|
F1 as Standard and Modifiable to F2
|
|
Mounting Holes
|
|
1 per foot
|
|
Nameplate
|
|
Stainless Steel
|
|
Paint
|
|
Buff, Alkyd
|
|
Relubrication
|
|
No
|
|
Rotor
|
|
Cast Aluminum
|
|
Service Factor
|
|
1.15
|
|
Temperature Rise1
|
|
80 ºC
|
|
Tests
|
|
NEMA Routine, IEEE 112-B
|
|
Time Rating
|
|
Continuous
|
|
Vibration
|
|
0.08 in/s
|
|
Warranty
|
|
36 months from date of purchase, 42 months from date of shipment, whichever occurs first
|
|
|
|
|
|
- Usable on 200 Volts, 60 Hz, same HP, at 1.0 service factor
- Usable on 200/400 V, 50 Hz, same HP, at 1.0 service factor
- Y-Start/Delta-Run Capable
- Usable on 200/400 V, 50 Hz at 1.15 SF and de-rated to next lower HP
|
|
|
|
- Oil & Gas
- Power & Energy
- Water/Wastewater
- Cement
- Pulp & Paper
- Metals
- Mining
- Chemical
|
|
|
|
- GEGARD1800™ Insulation System
The GEGARD1800 insulation system exceeds NEMA MG1-31 standards for motors operating on Inverter power at 460 or 575 volts. Other inverter capabilities include a 10:1 variable torque speed range along with a 4:1 constant torque. - Energy Savings
The Energy $aver TEFC meets US Government EIS Act efficiency levels and also meets NEMA Premium efficiency levels. This motor design has been tested per IEEE 112 Method B to ensure those efficiencies are met. Because of this, energy savings vs. a Pre-EPACT or EPACT motor are significant. For instance, a 100 HP PreEPACT 4 Pole TEFC motor operating 8760 hrs/yr at a rate of $0.06/kWH replaced with a similar Energy $aver TEFC-SD will save you over $1800 every year in energy costs! - Severe Duty
The Energy $aver frame, end shields, fan cover and conduit box are a rugged cast iron construction. It includes a recessed steel reinforced neoprene sling to minimize contaminants from entering the bearing cavity. Additional HP is available at 1.15 service factor for severe applications. A non-hygroscopic, anti-fungus Class F insulation is included, with an 80°C (NEMA B) temperature rise. A 0.08 in/sec vibration meets the IEEE 841 Standard and Y-Start/Delta Runs are designed for 210-320 motor frames. - 60/50 Hz Operation
- 320 Frame and below - 200/400 V @ 50 Hz
- 286 Frame and below - 200 V @ 60 Hz
|
|
|
|
|
|
|
|
 |
|
|
|
|
|