DV-300™ DC Drives
|
 |
Check up to five results to perform an action.
|
 |
 |
|
 |
The DV-300 is a 3-phase, six-pulse converter which is available in either non-regenerative or fully regenerative design. The DV-300 drive controller allows for precise regulation of motor speed, current, and field (field weakening and field economy are standard). This performance and chassis packaging allows the DV-300 to be applied easily in a wide array of industries including textiles, paper converting, plastics converting, corrugating, wire drawing, rubber and plastics, metal processing, machine tools, material handling, and more.
To allow for easy start-up, the DV-300 offers two choices: an optional keypad programmer or the standard GE toolbox. The Windows®-based GE toolbox enables the user to set parameters and program converter I/O and self-tune the regulators. Archiving the drive setup allows the user to have preconfigured setups available for similar applications. These are easily maintained and save valuable time.
The DV-300 drive can handle difficult applications and complex operations with the addition of the digital general function (DGF) card. The DGF card is an optional Intel® microprocessor-based board which allows application specific regulators, provides special sequencing operations, and solves other drive control challenges.
A wide range of advanced communication capabilities are available for the DV-300 drive. The drive communicates on a high-speed serial link including the following protocol options: DeviceNet™, Profibus-DP, Interbus-S, and Genius®. These communication options allow the drive, system control, and the data collection system to be easily integrated. Other options for the DV-300 include additional I/O, removable keypad programmer, and keypad door-mount kit.
|
 |
|
|
|
| |
 |
|
 |
|
 |
|
 |
|
 |
|
 |
 |
|
6KDV3017Q4F10
|
 |
17
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
10 A
|
 |
$4,000.00
|
 |
 |
|
6KDV3035Q4F10
|
 |
35
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
10 A
|
 |
$4,200.00
|
 |
 |
|
6KDV3056Q4F10
|
 |
56
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
10 A
|
 |
$4,500.00
|
 |
 |
|
6KDV3088Q4F14
|
 |
88
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
14 A
|
 |
$4,900.00
|
 |
 |
|
6KDV3112Q4F14
|
 |
112
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
14 A
|
 |
$5,100.00
|
 |
 |
|
6KDV3148Q4F14
|
 |
148
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
14 A
|
 |
$5,600.00
|
 |
 |
|
6KDV3224Q4F20
|
 |
224
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
20 A
|
 |
$7,500.00
|
 |
 |
|
6KDV3280Q4F20
|
 |
280
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
20 A
|
 |
$8,200.00
|
 |
 |
|
6KDV3336Q4F20
|
 |
336
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
20 A
|
 |
$10,400.00
|
 |
 |
|
6KDV3400Q4F20
|
 |
400
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
20 A
|
 |
$10,900.00
|
 |
 |
|
6KDV3450Q4F20
|
 |
450
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
20 A
|
 |
$11,900.00
|
 |
 |
|
6KDV3560Q4F25
|
 |
560
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
25 A
|
 |
$17,900.00
|
 |
 |
|
6KDV3850Q4F25
|
 |
850
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
25 A
|
 |
$20,900.00
|
 |
 |
|
6KDV31300Q4F40
|
 |
1300
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
40 A
|
 |
$24,433.00
|
 |
 |
|
6KDV31350Q4F40
|
 |
1350
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
40 A
|
 |
$25,577.00
|
 |
 |
|
6KDV31500Q4F40
|
 |
1500
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
40 A
|
 |
$27,025.00
|
 |
 |
|
6KDV31800Q4F40
|
 |
1800
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
40 A
|
 |
$31,411.00
|
 |
 |
|
6KDV32000Q4F40
|
 |
2000
|
 |
4 quadrants (Regenerative/Reversing)
|
 |
500/max Vac for Q3
|
 |
40 A
|
 |
$38,780.00
|
 |
 |
|
6KDV3017Q2B10
|
 |
17
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
10 A
|
 |
$3,700.00
|
 |
 |
|
6KDV3035Q2B10
|
 |
35
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
10 A
|
 |
$3,900.00
|
 |
 |
|
6KDV3056Q2B10
|
 |
56
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
10 A
|
 |
$4,000.00
|
 |
 |
|
6KDV3088Q2B14
|
 |
88
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
14 A
|
 |
$4,150.00
|
 |
 |
|
6KDV3112Q2B14
|
 |
112
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
14 A
|
 |
$4,400.00
|
 |
 |
|
6KDV3148Q2B14
|
 |
148
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
14 A
|
 |
$4,800.00
|
 |
 |
|
6KDV3224Q2B20
|
 |
224
|
 |
2 quadrants (Non-Regenerative/Non-Reversing)
|
 |
500/max Vac for Q4
|
 |
20 A
|
 |
$6,400.00
|
 |
|
|
|
|
|
|