3 HP, 1760 RPM, NEMA Frame 182T, 230/460 V
- Three Phase
- Cast Iron Frame
- Rigid Base
- Division I, Division II, with Conduit Box and Normally Closed Thermostats
- Explosion-Proof Motors are Class I, Groups C & D-Class II, Groups F & G
- All Ratings are Inverter Rated
- These explosion-proof motors are not designed for vertical mounting
- EPACT motors
Explosion-proof For Hazardous Locations
Underwriters Laboratories And Canadian Standards Association Listed
General Specifications:
These explosion-proof motors more
3 HP, 1760 RPM, NEMA Frame 182T, 230/460 V
- Three Phase
- Cast Iron Frame
- Rigid Base
- Division I, Division II, with Conduit Box and Normally Closed Thermostats
- Explosion-Proof Motors are Class I, Groups C & D-Class II, Groups F & G
- All Ratings are Inverter Rated
- These explosion-proof motors are not designed for vertical mounting
- EPACT motors
Explosion-proof For Hazardous Locations
Underwriters Laboratories And Canadian Standards Association Listed
General Specifications:
These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.
Features: - Rugged mechanical construction meeting all requirements for safety. UL and CSA listed.
- Double shielded, pre-lubricated ball bearings are standard.
- All motors have inherent automatic overload protection.
- NEMA 1.15 service factor except as noted.
Explosion-proof conduit box included at no extra cost. - Normally-closed thermostats are standard on cast iron motors.
- >Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence.
- Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence.
Application Notes:
These motors must be applied in accordance with the National Electrical Code, Article #500. A partial listing of explosive agents is noted below. Consult NFPA Publication 497M for a complete listing. Please note headings and footnotes for qualifications of specific LEESON motors.
Unit of Measure
Specifications
Base |
N/A Rigid Base |
Phase |
N/A Three |
HP |
N/A 3 |
RPM 60 Hz |
N/A 1760 |
Voltage |
N/A 230 V460 V |
FL Amps 460 V |
N/A 4.2 |
% FL Eff. |
N/A 87.5 |
NEMA Frame |
N/A 182T |
Disc. Sym. |
N/A C |
C Dimension |
N/A 17.12 in |
Approx. Weight |
N/A 100 lbs |
NEMA Service Factor |
N/A 1.15 |
Frame Construction |
N/A Cast Iron |
Agency Approvals |
N/A
![]() Loading zoom EPACT Mandates |
Manufacturer |
N/A
![]() Loading zoom Leeson |
Technical Details
N/A
Class I Group A: Acetylene Group B: Butadiene, ethylene oxide, hydrogen, propylene oxide, manufactured gases containing more than 30% hydrogen by volume. Group C: Acetaldehyde, cyclopropane, diethyl ether, ethylene. Group D: Acetone, acrylonitrile, ammonia, benzene, butane, ethanol, ethylene dichloride, gasoline, hexane, isoprene, methane (natural gas), methanol, naphtha, propane, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylene. Class II Group E: Aluminum, magnesium and other metal dusts with similar characteristics. Group F: Carbon black, coke or coal dust. Group G: Flour, starch or grain dust. |