- Single Phase
- C Face with Base
- Division I, Division II, Class I, Groups C & D-Class II, Groups F & G w/Conduit Box
Explosion-proof for hazardous locations
Underwriters Laboratories and Canadian Standards Association Listed
General Specifications:
These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.
Application Notes:
These motors must be applied in more
- Single Phase
- C Face with Base
- Division I, Division II, Class I, Groups C & D-Class II, Groups F & G w/Conduit Box
Explosion-proof for hazardous locations
Underwriters Laboratories and Canadian Standards Association Listed
General Specifications:
These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.
Application Notes:
These motors must be applied in accordance with the National Electrical Code, Article #500. A partial listing of explosive agents is noted below. Consult NFPA Publication 497M for a complete listing. Please note subheads above each column for qualifications of LEESON motors.
Specifications
Base |
N/A C Face with Base |
Enclosure Type |
N/A Totally Enclosed Fan Cooled |
Phase |
N/A Single |
HP |
N/A 1 |
RPM 60 Hz |
N/A 3450 |
Voltage |
N/A 115 V208 V230 V |
Overload Protection |
N/A Automatic |
FL Amps 230 V |
N/A 6.3 |
% FL Eff. |
N/A 70.0 |
NEMA Frame |
N/A 56C |
Disc. Sym. |
N/A A |
C Dimension |
N/A 14.44 in |
Approx. Weight |
N/A 50 lbs |
Manufacturer |
N/A
![]() Loading zoom Leeson |
Features
N/A
56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. |
Technical Details
N/A
Class I Group A: Acetylene Group B: Butadiene, ethylene oxide, hydrogen, propylene oxide, manufactured gases containing more than 30% hydrogen by volume. Group C: Acetaldehyde, cyclopropane, diethyl ether, ethylene. Group D: Acetone, acrylonitrile, ammonia, benzene, butane, ethanol, ethylene dichloride, gasoline, hexane, isoprene, methane (natural gas), methanol, naphtha, propane, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylene. Class II Group E: Aluminum, magnesium and other metal dusts with similar characteristics. Group F: Carbon black, coke or coal dust. Group G: Flour, starch or grain dust. |