1/2 HP, 230 V
230 Vac, 3-Phase Output
230 Vac, 3-Phase Output
Unit of Measure
Specifications
|
Environmental Conditions
|
Standards
|
Input Power Supply
|
Output
|
Control
|
Logic Controller (LC)
|
Process Controller (PI)
|
Indication
Specifications
Voltage (AC) |
N/A 230 V |
Phase |
N/A Single |
Input Frequency |
N/A 50/60 Hz |
HP |
N/A 1/2 |
kW |
N/A 0.37 |
Amps |
N/A 2.2 |
Efficiency1 | N/A 95.6 |
Watt Loss2 | N/A 25.0 |
Height |
N/A 6.13 in |
Width |
N/A 2.76 in |
Depth |
N/A 6.06 in |
NEMA 1 Kit |
N/A NEMA1LP1 |
Din Rail Mounting Kit |
N/A RMACLP1 |
Unit Size |
N/A M1 |
Weight |
N/A 2.43 lbs |
Accessories |
N/A
DEPLTACLP1, De-Coupling Plate Kit for 2 HP at 230 V/3 HP at 460 V and Below Drives ($15.00) DEPLTACLP2, De-Coupling Plate Kit for 3 HP at 230 V/5 HP at 460 V and Below Drives ($15.00) DEPLTACLP3, De-Coupling Plate Kit for 15 HP at 460 V and Above Drives ($20.00) KYPDACLP1, Replacement AF-60 LP Keypad with Potentiometer ($60.00) NEMA1ACLP1, NEMA 1 Kit for 1 HP and Below Drives ($30.00) NEMA1ACLP2, NEMA 1 Kit for 2 HP at 230 V/3 HP at 460 V and Below Drives ($35.00) NEMA1ACLP3, NEMA 1 Kit for 3 HP at 230V/5 HP at 460 V and Below Drives ($40.00) NEMA1ACLP4, NEMA 1 Kit for 15 HP and 20 HP at 460 V Drives ($45.00) NEMA1ACLP5, NEMA 1 Kit for 25 HP and 30 HP at 460 V Drives ($50.00) RMACLP1, DIN Rail Mounting Kit for 1 HP and Below Drives ($20.00) RMKYPDACLP1, Remote Mounting Kit for Keypad ($25.00) |
Factory Installed Keypad |
N/A Keypad |
Enclosure Type |
N/A IP20/Open |
Revision |
N/A 1st Revision |
Environmental Conditions
Enclosure |
N/A IP20 (NEMA 1 with optional NEMA 1 kit) |
Installation Location |
N/A Do not install in locations where product could be exposed to dust, corrosive gas, inflammable gas, oil mist, vapor, water drops or direct sunlight. There must be no salt in the atmosphere. Condensation must not be caused by sudden changes in temperature. For use at altitudes of 3280 ft. (1000 M) or less without derating. |
Ambient Temperature |
N/A -10 to +50 ºC |
Ambient Humidity |
N/A 5 to 95 % RH (non-condensing) |
Vibration |
N/A 1.0 g |
Storage Temperature |
N/A -25 to 65 ºC |
Standards
Approvals |
N/A
CE, UL, cUL, and C-Tick Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes for 230 V and 460 V. WEEE and RoHS Compliant |
Input Power Supply
Rated Input AC Voltage |
N/A 200-240 Vac, 1-phase, 50-60 Hz, ± 10 % V 200-240 Vac, 3-phase, 50-60 Hz, ± 10 % V 380-480 Vac, 3-phase, 50-60 Hz, ± 10 % V |
Max. Voltage Imbalance |
N/A 3 % of rated supply voltage |
True Power Factor |
N/A > 0.4 nominal at rated load |
Displacement Power Factor |
N/A > 0.98 |
Switching on Input Power Supply |
N/A Maximum twice/minute |
Environment According to EN60664-1 |
N/A Overvoltage category III/pollution degree 2 |
Output
Rated Output Voltage |
N/A 0-100 % of supply voltage |
Output Frequency |
N/A 0-200 Hz (Adv. Vector Control Plus Mode) 0-400 Hz (Volts/Hertz Mode) |
Switching on Output |
N/A Unlimited |
Accel/Decel Times |
N/A 0.05 to 3600 s |
Overload Current Rating |
N/A 150 % of drive rated current for 1 minute |
Control
Control Method |
N/A Sinusoidal PWM Control (V/Hz with torque vector control) |
Switching Frequency Select |
N/A 2 kHz4 kHz8 kHz12 kHz16 kHz |
Operation Method |
N/A
Keypad operation: Hand, Off, Auto Digital Input: Programmable for Start/Stop, Forward/Reverse, Jog Timer operation: Stop after predetermined time frame Link operation: RS-485 Modbus RTU |
Frequency Reference Setting |
N/A Up or Down buttons on keypad or external reference |
Analog Input |
N/A
Built in Potentiometer 0-10 Vdc analog input 4-20 ma analog input |
Preset Speeds |
N/A 8 presets via digital inputs |
Link Operation |
N/A Drive RS-485 or Modbus RTU |
Second Reference Setting |
N/A Switch from speed reference 1 to reference 2 via digital input |
Trim Reference Setting |
N/A Available for speed reference offset via potentiometer, voltage input, or current input |
Acceleration/Deceleration Time |
N/A
0.05-3600 seconds (two acceleration and deceleration rates are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or S-curve |
DC Injection Braking |
N/A
Starting frequency: 0.0 to 400 Hz Braking time: 0.0 to 60.0 seconds Braking level: 0-150 % of rated current |
Frequency Limit |
N/A 0 to 400 Hz |
Jump Frequency Control |
N/A 2 jump (or skip) frequencies via parameter set to avoid mechanical vibration |
Jogging Operation |
N/A Operation via On key or digital input (Fwd or Rev) |
Auto-Restart After Power Failure |
N/A Restarts the drive without stopping after instantaneous power failure |
Slip Compensation |
N/A Maintains motor at constant speed with load fluctuations |
Energy Savings |
N/A Controls output voltage to minimize motor loss during constant speed operation |
Start Mode Function |
N/A This functionality smoothly catches a spinning motor |
Logic Controller (LC)
Logic Controller Events |
N/A Over 23 types of Programmable Events |
Comparators |
N/A Array of 4 Comparators |
Timers |
N/A Array of 3 Timers, adjustable from 0.0 to 3600 sec |
Logic Rules |
N/A Array of 4 Boolean Logic Rules |
Logic Controller States |
N/A Array of 20 Logic Controller Action States |
Process Controller (PI)
Process CL Feedback Select |
N/A Analog input 1 Analog input 2 Local bus reference No function Pulse input |
Process PI Control |
N/A Inverse Normal |
Process PI Anti Windup |
N/A Disabled Enabled |
Process PI Start Speed |
N/A 0.0 to 200 Hz |
Process PI Proportional Gain |
N/A 0.00 to 10.00 |
Process PI Integral Gain |
N/A 0.10 to 9999 s |
Process PI Feed Forward Factor |
N/A 0 to 400 % |
On Reference Bandwidth |
N/A 0 to 200 % |
- 1 At rated load conditions
- 2 At rated load conditions