40 HP, 1770 RPM, NEMA Frame 324T, 230/460 V
  • Three Phase
  • Cast Iron Frame
  • Rigid Base
  • Division I, Division II, with Conduit Box and Normally Closed Thermostats
  • Explosion-Proof Motors are Class I, Groups C & D-Class II, Groups F & G
  • All Ratings are Inverter Rated
  • These explosion-proof motors are not designed for vertical mounting
  • EPACT motors

    Explosion-proof For Hazardous Locations
    Underwriters Laboratories And Canadian Standards Association Listed
    General Specifications:
    These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.

    Features:
  • Rugged mechanical construction meeting all requirements for safety. UL and CSA listed.
  • Double shielded, pre-lubricated ball bearings are standard.
  • All motors have inherent automatic overload protection.
  • NEMA 1.15 service factor except as noted.
    Explosion-proof conduit box included at no extra cost.
  • Normally-closed thermostats are standard on cast iron motors.
  • >Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence.
  • Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence.

    Application Notes:
    These motors must be applied in accordance with the National Electrical Code, Article #500. A partial listing of explosive agents is noted below. Consult NFPA Publication 497M for a complete listing. Please note headings and footnotes for qualifications of specific LEESON motors.
Unit of Measure

Specifications

Base

N/A Rigid Base

Phase

N/A Three

HP

N/A 40

RPM 60 Hz

N/A 1770

Voltage

N/A 230 V460 V

FL Amps 460 V

N/A 51.5

% FL Eff.

N/A 93.0

NEMA Frame

N/A 324T

Disc. Sym.

N/A C

C Dimension

N/A 28.87 in

Approx. Weight

N/A 525 lbs

NEMA Service Factor

N/A 1.00

Frame Construction

N/A Cast Iron

Agency Approvals

N/A
EPACT Mandates

Manufacturer

N/A
Leeson

Technical Details

N/A

    No LEESON motors are listed for Class I, Group A or B.
    Class I
    Group A: Acetylene
    Group B: Butadiene, ethylene oxide, hydrogen, propylene oxide, manufactured gases containing more than 30% hydrogen by volume.
    Group C: Acetaldehyde, cyclopropane, diethyl ether, ethylene.
    Group D: Acetone, acrylonitrile, ammonia, benzene, butane, ethanol, ethylene dichloride, gasoline, hexane, isoprene, methane (natural gas), methanol, naphtha, propane, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylene.

    Class II
    Group E: Aluminum, magnesium and other metal dusts with similar characteristics.
    Group F: Carbon black, coke or coal dust.
    Group G: Flour, starch or grain dust.

Features

N/A

  • 1.0 Service Factor
  • Rugged mechanical construction meeting all requirements for safety. UL and CSA listed.
  • Double shielded, pre-lubricated ball bearings are standard.
  • All motors have inherent automatic overload protection.
  • NEMA1.0 Service Factor except as noted.
  • Explosion-proof conduit box included at no extra cost.
  • Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence.
  • Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence.