3 HP, 3450 RPM, NEMA Frame 56C, 230 V
  • Keyed Shaft
  • Drip-Proof
  • Single Phase
  • Less Base
General Specifications:
Stator impregnated with extra heavy varnish system. High temperature copper magnet wire provides extended motor life. "Super Hush" flow-through ventilation system (exhaust shaft-end) standard. Vertical or horizontal mounting (drip-cover available). Ground provision. Die cast aluminum NEMA 56 C face mounting flange, with cast iron bearing seat insert. Mechanical bearing lock-shaft-end, for longer life. Reliable, field proven, corrosion resistant rotating switch. High overload capacities provided by service factor. Neoprene shaft flinger on J frame motors protects bearings by repelling moisture and other contaminants.

Shaft Material:
Keyed shafts are made of carbon steel. Threaded shafts are 416 stainless steel. Shafts are CW rotation, facing lead end.

Bearings:
203 Double-sealed ball bearing, shaft-end; 203 Double-shielded ball bearing, switch-end. Shaft-end bearing is locked to limit axial movement of the shaft.

Terminal Board:
1/4" Quick connects (keyed shaft motors are reversible).

U.L. and C.S.A. Recognized:
Motor components (UL File No. E57948).
Class "B" insulation system (UL File No. E55555).
Thermal protector/winding combination (UL No. E57955) through 1 HP C.S.A. listed through 1 HP (Report No. LR33543).
Unit of Measure

Specifications

Base

N/A Less Base

Enclosure Type

N/A Drip-Proof

Phase

N/A Single

HP

N/A 3

RPM 60 Hz

N/A 3450

Voltage

N/A 230 V

Overload Protection

N/A Automatic

FL Amps 230 V

N/A 12.8

NEMA Frame

N/A 56C

Disc. Sym.

N/A A

C Dimension

N/A 13.55 in

Approx. Weight

N/A 49 lbs

NEMA Service Factor

N/A 1.15

Manufacturer

N/A
Leeson

Features

N/A

  • Capacitor start/capacitor run designed for reduced amperage, others are capacitor start/induction run.