3/4 HP, 1140 RPM, NEMA Frame 56C, 208/230/460 V, TENV/TEFCWashguard SST All-stainless Three-phase TENV/TEFC C Face less Base
Stainless Steel Tough for demanding washdown applications All exterior components of 300 series stainless steel, including motor frame, endshield and conduit box castings Moisture resistant sealant between frame and endbells Full-fact nameplate is laser-etched on the motor frame Built to withstand the demanding washdown environments found in the food processing, chemical processing and beverage industries No paint or coatings of any type used on the exterior of the motor Four locations for T-drains provided on each endshield IRIS™ insulation system Meets IP55 enclosure protection Three phase motors are suitable use on VFDs 10:1 ratio for constant or variable torque at 1.0 SF
Mechanical Protection Features:
All exterior components - frame, base, endshields, fan guard, shaft, hardware, conduit box and cover - are made from 300 series stainless steel for maximum corrosion resistance. Nameplate data is permanently laser-etched into the motor frame - no Mylar nameplate that can wash off or riveted metal nameplate to trap dirt. No paint or any type of coating is used on the exterior of the motor. Sealant is applied to endshield and frame fits before assembly to prevent water entry. Shaft seals on both ends of TEFC motors - shaft end only on TENV. Double-sealed bearings have high performance Exxon Polyrex EM grease. Conduit box is fully gasketed half-split design with flanged cover and body gasket with lead separator. Anticorrosion coating on rotor prevents corrosion. Four quadrant drain locations on each endbell allow drainage of condensation in any mounting position. Stainless steel T-drains are provided to prevent liquids from splashing into the drain locations. Motors are shipped with a T-drain assembled in the six o'clock position on the opposite endshield. Another T-drain is shipped loose in the conduit box for installation at the lowest point of the shaft-end endshield. For a totally sealed motor, a spare pipe plug is included to replace the pre-installed T-drain. Mechanical performance is further enhanced by over-sized bearings, heavy 12 gauge base, shaft-end bearing is locked internally to limit axial endplay, and specially designed shaft extension resists breakage at bearing journal.
Electrical Performance and Protection Features:
FHP Washguard SST full load efficiencies meet EPACT standards for non-exempt motors when tested without shaft seals. For extra moisture resistance, windings are immersed and cured in polyester insulating varnish. LEESON’s exclusive IRIS™ Inverter-Rated Insulation System provides extra protection and long life, especially in inverter driven applications. 20:1 Constant Torque Operation
Standards and Approvals:
UL component recognized, file number E57948, guide number PRGY2. Energy efficiency ratings are verified by an independent testing laboratory. CSA Energy Efficiency Verification Program, report number EEV 78720-1.
Construction is CSA Certified for safety report number LR33543. Motor is CE marked for European acceptance.
Stainless Steel Tough for demanding washdown applications
Mechanical Protection Features:
All exterior components - frame, base, endshields, fan guard, shaft, hardware, conduit box and cover - are made from 300 series stainless steel for maximum corrosion resistance. Nameplate data is permanently laser-etched into the motor frame - no Mylar nameplate that can wash off or riveted metal nameplate to trap dirt. No paint or any type of coating is used on the exterior of the motor. Sealant is applied to endshield and frame fits before assembly to prevent water entry. Shaft seals on both ends of TEFC motors - shaft end only on TENV. Double-sealed bearings have high performance Exxon Polyrex EM grease. Conduit box is fully gasketed half-split design with flanged cover and body gasket with lead separator. Anticorrosion coating on rotor prevents corrosion. Four quadrant drain locations on each endbell allow drainage of condensation in any mounting position. Stainless steel T-drains are provided to prevent liquids from splashing into the drain locations. Motors are shipped with a T-drain assembled in the six o'clock position on the opposite endshield. Another T-drain is shipped loose in the conduit box for installation at the lowest point of the shaft-end endshield. For a totally sealed motor, a spare pipe plug is included to replace the pre-installed T-drain. Mechanical performance is further enhanced by over-sized bearings, heavy 12 gauge base, shaft-end bearing is locked internally to limit axial endplay, and specially designed shaft extension resists breakage at bearing journal.
Electrical Performance and Protection Features:
FHP Washguard SST full load efficiencies meet EPACT standards for non-exempt motors when tested without shaft seals. For extra moisture resistance, windings are immersed and cured in polyester insulating varnish. LEESON’s exclusive IRIS™ Inverter-Rated Insulation System provides extra protection and long life, especially in inverter driven applications. 20:1 Constant Torque Operation
Standards and Approvals:
UL component recognized, file number E57948, guide number PRGY2. Energy efficiency ratings are verified by an independent testing laboratory. CSA Energy Efficiency Verification Program, report number EEV 78720-1.
Construction is CSA Certified for safety report number LR33543. Motor is CE marked for European acceptance.
Unit of Measure