Items |
111074 Leeson Single Phase Rigid Base Explosion-Proof Motors |
111084 Leeson Single Phase Rigid Base Explosion-Proof Motors |
110934 Leeson Single Phase Rigid Base Explosion-Proof Motors |
110961 Leeson Single Phase Rigid Base Explosion-Proof Motors |
||||
% FL Eff. | N/A 63.0 | N/A 65.0 | N/A 70.0 | N/A 75.0 | ||||
Approx. Weight | N/A 35 lbs | N/A 41 lbs | N/A 46 lbs | N/A 47 lbs | ||||
Base | N/A Rigid Base | |||||||
C Dimension | N/A 12.38 in | N/A 13.94 in | N/A 14.44 in | N/A 14.44 in | ||||
Disc. Sym. | N/A A | |||||||
Enclosure Type | N/A Totally Enclosed Non-Ventilated | N/A Totally Enclosed Fan Cooled | N/A Totally Enclosed Fan Cooled | N/A Totally Enclosed Fan Cooled | ||||
FL Amps 230 V | N/A 2.9 | N/A 4.4 | N/A 5.5 | N/A 6.7 | ||||
HP | N/A 1/3 | N/A 1/2 | N/A 3/4 | N/A 1 | ||||
NEMA Frame | N/A 56 | N/A 56H | N/A 56H | N/A 56H | ||||
Features |
N/A
These motors are totally enclosed, non-ventilated.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
N/A
56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
N/A
56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
N/A
56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
||||
Overload Protection | N/A Automatic | |||||||
Phase | N/A Single | |||||||
RPM 60 Hz | N/A 1725 | |||||||
Voltage | N/A 115 V208 V230 V | |||||||
Manufacturer |
N/A
Leeson |
|||||||
|