    General Specifications:
    These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.

    Application Notes:
    These motors must be applied in accordance with the National Electrical Code, Article #500. A partial listing of explosive agents is noted below. Consult NFPA Publication 497M for a complete listing. Please note subheads above each column for qualifications of LEESON motors.
Unit of Measure

Specifications

Base

N/A C Face Less Base

Enclosure Type

N/A Totally Enclosed Non-Ventilated

Phase

N/A Single

HP

N/A 1/3

RPM 60 Hz

N/A 3450

Voltage

N/A 115 V208 V230 V

Overload Protection

N/A Automatic

FL Amps 230 V

N/A 2.2

% FL Eff.

N/A 65.0

NEMA Frame

N/A 56C

Disc. Sym.

N/A A

C Dimension

N/A 12.88 in

Approx. Weight

N/A 38 lbs

Manufacturer

N/A
Leeson

Features

N/A

  • These motors are totally enclosed, non-ventilated.

Technical Details

N/A

    No LEESON motors are listed for Class I, Group A or B.
    Class I
    Group A: Acetylene
    Group B: Butadiene, ethylene oxide, hydrogen, propylene oxide, manufactured gases containing more than 30% hydrogen by volume.
    Group C: Acetaldehyde, cyclopropane, diethyl ether, ethylene.
    Group D: Acetone, acrylonitrile, ammonia, benzene, butane, ethanol, ethylene dichloride, gasoline, hexane, isoprene, methane (natural gas), methanol, naphtha, propane, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylene.

    Class II
    Group E: Aluminum, magnesium and other metal dusts with similar characteristics.
    Group F: Carbon black, coke or coal dust.
    Group G: Flour, starch or grain dust.