COMPANY HEADER
Print Back
3/4 HP, 1725 RPM, NEMA Frame 56H, 115/208/230 V
  • Single Phase
  • Rigid Base
  • Division I, Division II, Class I, Groups C & D - Class II, Groups F & G w/conduit Box

    Explosion-proof for hazardous locations
    Underwriters Laboratories and Canadian Standards Association Listed
    General Specifications:
    These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.

    Application Notes:
    These motors must be applied in accordance with the National Electrical Code, Article #500. A partial listing of explosive agents is noted below. Consult NFPA Publication 497M for a complete listing. Please note subheads above each column for qualifications of LEESON motors.
Unit of Measure

Specifications

% FL Eff.

N/A 70.0

Approx. Weight

N/A 46 lbs

Base

N/A Rigid Base

C Dimension

N/A 14.44 in

Disc. Sym.

N/A A

Enclosure Type

N/A Totally Enclosed Fan Cooled

FL Amps 230 V

N/A 5.5

HP

N/A 3/4

NEMA Frame

N/A 56H

Overload Protection

N/A Automatic

Phase

N/A Single

RPM 60 Hz

N/A 1725

Voltage

N/A 115 V208 V230 V

Manufacturer

N/A
Leeson

Features

N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost.
Capacitors on single phase designs are mounted inside the motor frame.
Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence.
Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence.

Technical Details

N/A

    No LEESON motors are listed for Class I, Group A or B.
    Class I
    Group A: Acetylene
    Group B: Butadiene, ethylene oxide, hydrogen, propylene oxide, manufactured gases containing more than 30% hydrogen by volume.
    Group C: Acetaldehyde, cyclopropane, diethyl ether, ethylene.
    Group D: Acetone, acrylonitrile, ammonia, benzene, butane, ethanol, ethylene dichloride, gasoline, hexane, isoprene, methane (natural gas), methanol, naphtha, propane, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylene.

    Class II
    Group E: Aluminum, magnesium and other metal dusts with similar characteristics.
    Group F: Carbon black, coke or coal dust.
    Group G: Flour, starch or grain dust.