| HP and Voltage | N/A 25 hp, 230 V 50 hp, 460 V | 
| Output DC (Nominal Current) | N/A 88 | 
| Number of Quadrants | N/A 4 quadrants (Regenerative/Reversing) | 
| Voltage Rating | N/A 500/max Vac for Q3 | 
| Rated Field Current | N/A 14 A | 
| Catalog No. | N/A D6143 | 
| Height | N/A 14.2 in | 
| Width | N/A 10.4 in | 
| Depth | N/A 10.8 in | 
| Weight | N/A 27.6 lbs | 
| Accessories | N/A
                                                                                          6KCV300CTI, RS 485/232 Converter ($170.00) 6KCV300DCN, DeviceNet Option Card (DGF Card Required) ($240.00) 6KCV300DGF, Digital General Function Card ($1,230.00) 6KCV300DVN, SBI DeviceNet Option Card (without DGF) ($745.00) 6KCV300INS, Interbus-S Bus Communication Option Card ($805.00) 6KCV300KPM, External Keypad Mounting Kit ($75.00) 6KCV300KPU, AV/DV-300 Keypad Programmer ($290.00) 6KCV300PDP, Profibus-DP Bus Communication Option Card ($745.00) 6KCV300TBO, I/O Expansion Option Card (Discrete and Analog) ($230.00) 6KCV300WPD, Win+Drive ($5,000.00) 6KDV300DES, Digital Encoder to Sinusoidal Converter (DIN rail mount) ($220.00) HE300GEN200, Genius Communication Option Card ($1,450.00) | 
| Notes | N/A Please contact customer service for latest revision. | 
| Four Accel/Decel Ramps | N/A Each independently adjustable from 0-65,000 s | 
| Ramp Types: Linear, S-Curve | N/A S-curve shape is adjustable through special time constant parameters | 
| Min./Max. Speed Limits | N/A With independent adjustments for forward and reverse speeds | 
| Adjustable Current Limits (Motoring and Braking) | N/A 150 % for 60 s standard | 
| Seven Preset Speeds | N/A Selectable through three contact closures | 
| Password Protection | N/A 5-digit combination, selectable by user | 
| Field Control | N/A Current regulation Disable (for external field supply) Field economy Field weakening voltage regulation | 
| Jog Functions | N/A
                                                                                          Reference from internal parameter or external reference potentiometer Can be programmed with or without linear time | 
| Zero Speed Functionality | N/A Includes zero speed level, zero speed threshold, and delay detection | 
| Tach Feedback Bypass | N/A Drive automatically switches to armature voltage feedback if the tach signal is lost | 
| Catch-a-Spinning Motor (Auto Capture) | N/A Allows restart of drive with a rotating motor | 
| Reset to Default Parameters | N/A Aids in start-up and troubleshooting | 
| Faults Detected | N/A Communication card failure Enable sequence error Fault data history (last ten faults) Field loss Heatsink over temperature Motor over temperature Motor overload Option card failure Overcurrent Over voltage/under voltage Tach loss User's external faults | 
| Analog Inputs | N/A
                                                                                          Three differential, 12 bit Programmable and selectable for ± 10 Vdc, 0-20 mA; 0-10 Vdc, 4-20 mA | 
| Digital Inputs | N/A Four fixed 24 Vdc (enable, start/stop, fast stop, external fault) | 
| Digital Outputs | N/A
                                                                                          One drive OK normally open contact One programmable normally open contact | 
| Built-in RS 485 Communication Port | N/A Allows communication with drive for setup and troubleshooting | 
| Sinusoidal Encoder Input (with Internal 5 Vdc Available from Drive) | N/A Provides the best speed regulation | 
| Digital Tach (with Internal 24 Vdc Available from Drive) | N/A Utilizes standard digital tachometer for speed regulation | 
| DC Tach Input | N/A Utilizes analog dc tachometers for speed regulation | 
| Ambient Temperature | N/A 0 to 40 ºC | 
| Ambient Humidity | N/A 5 to 85 % RH (non-condensing) | 
| Altitude | N/A To 3300 ft (1000 m) without derating | 
| Enclosure | N/A IP20 - Open chassis | 
| Armature | N/A 230-500 Vac ± 10 %, 3-phase | 
| Control Power | N/A 115-230 Vac ± 10 %, 1-phase | 
| Field | N/A 230-460 Vac ± 10 %, 1-phase | 
| Features | N/A
                                                                                          Regenerative and Non-Regenerative 150 % Overload for 60 S Speed, Current, and CEMF Regulation 16 Bit Microprocessor | 
| Speed Regulation | N/A CEMF = 1 - 2 % DC tach = up to 0.1 % Digital encoder = 0.02 % Sinusoidal enc. = 0.01 % | 
| Options | N/A 2-line backlit, detachable, and removable keypad programmer Communications: DeviceNet, Profibus-DP, Interbus-S, and Genius DGF 386 (digital general function card) Remote keypad mounting kit | 
| TBO Digital or Analog Eexpansion Modules (Maximum of two) per TBO Board | N/A Four 24 Vdc digital inputs Four 24 Vdc digital outputs Two +10 Vdc analog outputs | 