Leeson Single Phase C Face Less Base Explosion-Proof Motors
Leeson Explosion-Proof
- Single Phase
- C Face less Base
- Division I, Division II, Class I, Groups C & D-Class II, Groups F & G w/Conduit Box
Explosion-proof for hazardous locations
Underwriters Laboratories and Canadian Standards Association Listed
General Specifications:
These explosion-proof motors are designed and approved for application in hazardous environments having certain explosive gases or materials present.
Application Notes:
These motors must be applied in accordance with the National Electrical Code, Article #500. A partial listing of explosive agents is noted below. Consult NFPA Publication 497M for a complete listing. Please note subheads above each column for qualifications of LEESON motors.
Item # |
HP |
RPM 60 Hz |
Voltage |
FL Amps 230 V |
NEMA Frame |
C Dimension |
Features |
Quantity | Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|---|---|
111095 111095/Asset/a1061.jpg | HP N/A 1/3 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 2.2 | NEMA Frame N/A 56C | C Dimension N/A 12.88 in |
Features
N/A
|
Request Quote | |
111075 111075/Asset/a1061.jpg | HP N/A 1/3 | RPM 60 Hz N/A 1725 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 2.9 | NEMA Frame N/A 56C | C Dimension N/A 12.37 in |
Features
N/A
|
Request Quote | |
111098 111098/Asset/a1061.jpg | HP N/A 1/2 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 4.2 | NEMA Frame N/A 56C | C Dimension N/A 13.44 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
116188 116188/Asset/a1061.jpg | HP N/A 1/2 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 3.8 | NEMA Frame N/A 56J | C Dimension N/A 13.96 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
111085 111085/Asset/a1061.jpg | HP N/A 1/2 | RPM 60 Hz N/A 1725 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 4.4 | NEMA Frame N/A 56C | C Dimension N/A 13.94 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
111097 111097/Asset/a1061.jpg | HP N/A 3/4 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 5.0 | NEMA Frame N/A 56C | C Dimension N/A 13.96 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
116186 116186/Asset/a1061.jpg | HP N/A 3/4 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 5.0 | NEMA Frame N/A 56J | C Dimension N/A 14.46 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
111086 111086/Asset/a1061.jpg | HP N/A 3/4 | RPM 60 Hz N/A 1725 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 5.5 | NEMA Frame N/A 56C | C Dimension N/A 14.44 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
111096 111096/Asset/a1061.jpg | HP N/A 1 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 6.2 | NEMA Frame N/A 56C | C Dimension N/A 14.44 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
116185 116185/Asset/a1061.jpg | HP N/A 1 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 6.0 | NEMA Frame N/A 56J | C Dimension N/A 14.96 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
110852 110852/Asset/a1061.jpg | HP N/A 1 | RPM 60 Hz N/A 1725 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 6.7 | NEMA Frame N/A 56C | C Dimension N/A 14.44 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
114424 114424/Asset/a1061.jpg | HP N/A 1 1/2 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 8.5 | NEMA Frame N/A 56C | C Dimension N/A 14.96 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
116183 116183/Asset/a1061.jpg | HP N/A 1 1/2 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 8.5 | NEMA Frame N/A 56J | C Dimension N/A 15.46 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
114425 114425/Asset/a1061.jpg | HP N/A 2 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 10.5 | NEMA Frame N/A 56C | C Dimension N/A 15.96 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote | |
116181 116181/Asset/a1061.jpg | HP N/A 2 | RPM 60 Hz N/A 3450 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 10.5 | NEMA Frame N/A 56J | C Dimension N/A 16.46 in |
Features
N/A 56H & 56HC motors have bases with mounting holes for NEMA 56 and NEMA143-5T and a standard NEMA 56C face and 5/8" shaft.Rugged mechanical construction meeting all requirements for safety. UL and CSA listed. Double shielded, pre-lubricated ball bearings are standard. All motors have inherent automatic overload protection. NEMA 1.0 Service Factor except as noted. Explosion-proof conduit box included at no extra cost. Capacitors on single phase designs are mounted inside the motor frame. Division I areas are environments where a hazard is present continuously or would be subject to fire or explosion if the hazard was present as a result of an accident or uncommon occurrence. Division II areas are environments where the threat of fire or explosion is not normally present and not likely to result in the event of an abnormal occurrence. |
Request Quote |