Lincoln Hydraulic Elevator Pump Motors
Lincoln
Hydraulic pump passenger, service, freight, and dumbwaiter low rise elevators. Typically hydraulic elevators travel up to 6 floors at speeds up to 200 fpm.
- Open Drip-Proof Construction
- 3-Phase
- Foot Mounted
- 10 to 100 HP
Hydraulic pump passenger, service, freight, and dumbwaiter low rise elevators. Typically hydraulic elevators travel up to 6 floors at speeds up to 200 fpm.
1 2
Item # |
HP |
SYN RPM |
Frame |
Volts |
80 Starts FL Amps |
Locked Rotor Amps |
Manufacturer |
Quantity | Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|---|---|
LM30091 LM30091/Asset/a1117.jpg | HP N/A 15 | SYN RPM N/A 3600 | Frame N/A 213T | Volts N/A 200 V | 80 Starts FL Amps N/A 41 | Locked Rotor Amps N/A 187 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30092 LM30092/Asset/a1117.jpg | HP N/A 15 | SYN RPM N/A 3600 | Frame N/A 213T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 18.0 35.5 | Locked Rotor Amps N/A 81 162 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28867 LM28867/Asset/a1117.jpg | HP N/A 15 | SYN RPM N/A 1800 | Frame N/A 215T | Volts N/A 200 V | 80 Starts FL Amps N/A 45.1 | Locked Rotor Amps N/A 170 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28868 LM28868/Asset/a1117.jpg | HP N/A 15 | SYN RPM N/A 1800 | Frame N/A 215T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 19.6 39.2 | Locked Rotor Amps N/A 74 148 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28869 LM28869/Asset/a1117.jpg | HP N/A 15 | SYN RPM N/A 1800 | Frame N/A 215T | Volts N/A 575 V | 80 Starts FL Amps N/A 15.7 | Locked Rotor Amps N/A 59.2 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30093 LM30093/Asset/a1117.jpg | HP N/A 20 | SYN RPM N/A 3600 | Frame N/A 215T | Volts N/A 200 V | 80 Starts FL Amps N/A 53.0 | Locked Rotor Amps N/A 267 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30094 LM30094/Asset/a1117.jpg | HP N/A 20 | SYN RPM N/A 3600 | Frame N/A 215T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 23.0 46.0 | Locked Rotor Amps N/A 116 232 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28873 LM28873/Asset/a1117.jpg | HP N/A 20 | SYN RPM N/A 1800 | Frame N/A 254T | Volts N/A 200 V | 80 Starts FL Amps N/A 59.1 | Locked Rotor Amps N/A 267 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28874 LM28874/Asset/a1117.jpg | HP N/A 20 | SYN RPM N/A 1800 | Frame N/A 254T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 25.7 51.4 | Locked Rotor Amps N/A 116 232 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28875 LM28875/Asset/a1117.jpg | HP N/A 20 | SYN RPM N/A 1800 | Frame N/A 254T | Volts N/A 575 V | 80 Starts FL Amps N/A 20.6 | Locked Rotor Amps N/A 93 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30095 LM30095/Asset/a1117.jpg | HP N/A 25 | SYN RPM N/A 3600 | Frame N/A 254T | Volts N/A 200 V | 80 Starts FL Amps N/A 66.5 | Locked Rotor Amps N/A 334 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30096 LM30096/Asset/a1117.jpg | HP N/A 25 | SYN RPM N/A 3600 | Frame N/A 254T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 29 58.0 | Locked Rotor Amps N/A 145 290 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28879 LM28879/Asset/a1117.jpg | HP N/A 25 | SYN RPM N/A 1800 | Frame N/A 256T | Volts N/A 200 V | 80 Starts FL Amps N/A 73.6 | Locked Rotor Amps N/A 368 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28880 LM28880/Asset/a1117.jpg | HP N/A 25 | SYN RPM N/A 1800 | Frame N/A 256T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 32 64.0 | Locked Rotor Amps N/A 160 320 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM28881 LM28881/Asset/a1117.jpg | HP N/A 25 | SYN RPM N/A 1800 | Frame N/A 256T | Volts N/A 575 V | 80 Starts FL Amps N/A 25.6 | Locked Rotor Amps N/A 128 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30097 LM30097/Asset/a1117.jpg | HP N/A 30 | SYN RPM N/A 3600 | Frame N/A 256T | Volts N/A 200 V | 80 Starts FL Amps N/A 80.0 | Locked Rotor Amps N/A 419 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30098 LM30098/Asset/a1117.jpg | HP N/A 30 | SYN RPM N/A 3600 | Frame N/A 256T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 34.5 69.0 | Locked Rotor Amps N/A 182 364 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM29850 LM29850/Asset/a1117.jpg | HP N/A 30 | SYN RPM N/A 1800 | Frame N/A 284T | Volts N/A 200 V | 80 Starts FL Amps N/A 84 | Locked Rotor Amps N/A 391 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM29851 LM29851/Asset/a1117.jpg | HP N/A 30 | SYN RPM N/A 1800 | Frame N/A 284T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 36.5 73.0 | Locked Rotor Amps N/A 170 340 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM29854 LM29854/Asset/a1117.jpg | HP N/A 30 | SYN RPM N/A 1800 | Frame N/A 284T | Volts N/A 575 V | 80 Starts FL Amps N/A 29.2 | Locked Rotor Amps N/A 136 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30099 LM30099/Asset/a1117.jpg | HP N/A 40 | SYN RPM N/A 3600 | Frame N/A 284T | Volts N/A 200 V | 80 Starts FL Amps N/A 112 | Locked Rotor Amps N/A 460 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM30100 LM30100/Asset/a1117.jpg | HP N/A 40 | SYN RPM N/A 3600 | Frame N/A 284T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 48.5 97 | Locked Rotor Amps N/A 200 400 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM29852 LM29852/Asset/a1117.jpg | HP N/A 40 | SYN RPM N/A 1800 | Frame N/A 286T | Volts N/A 200 V | 80 Starts FL Amps N/A 112 | Locked Rotor Amps N/A 495 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM29853 LM29853/Asset/a1117.jpg | HP N/A 40 | SYN RPM N/A 1800 | Frame N/A 286T | Volts N/A 230 V460 V | 80 Starts FL Amps N/A 48.5 97 | Locked Rotor Amps N/A 215 430 |
Manufacturer
N/A Lincoln |
Request Quote | |
LM29855 LM29855/Asset/a1117.jpg | HP N/A 40 | SYN RPM N/A 1800 | Frame N/A 286T | Volts N/A 575 V | 80 Starts FL Amps N/A 38.8 | Locked Rotor Amps N/A 172 |
Manufacturer
N/A Lincoln |
Request Quote |
1 2