Item # |
HP |
RPM 60 Hz |
Voltage |
FL Amps 230 V |
NEMA Frame |
C Dimension |
Mechanical Features |
Electrical Features |
Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|---|---|
191474 191474/Asset/a1054.jpg | HP N/A 1/2 | RPM 60 Hz N/A 3600 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 3.1 | NEMA Frame N/A 56C | C Dimension N/A 11.1 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191475 191475/Asset/a1054.jpg | HP N/A 1/2 | RPM 60 Hz N/A 1800 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 4.1 | NEMA Frame N/A 56C | C Dimension N/A 11.1 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191476 191476/Asset/a1054.jpg | HP N/A 3/4 | RPM 60 Hz N/A 3600 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 4.5 | NEMA Frame N/A 56C | C Dimension N/A 11.8 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191477 191477/Asset/a1054.jpg | HP N/A 3/4 | RPM 60 Hz N/A 1800 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 4.9 | NEMA Frame N/A 56C | C Dimension N/A 11.8 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191478 191478/Asset/a1054.jpg | HP N/A 1 | RPM 60 Hz N/A 3600 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 6.2 | NEMA Frame N/A 56C | C Dimension N/A 12.3 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191479 191479/Asset/a1054.jpg | HP N/A 1 | RPM 60 Hz N/A 1800 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 6.8 | NEMA Frame N/A 56C | C Dimension N/A 12.3 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191480 191480/Asset/a1054.jpg | HP N/A 1 1/2 | RPM 60 Hz N/A 3600 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 8.8 | NEMA Frame N/A 56C | C Dimension N/A 13.20 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191481 191481/Asset/a1054.jpg | HP N/A 1 1/2 | RPM 60 Hz N/A 1800 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 9.5 | NEMA Frame N/A 56C | C Dimension N/A 13.20 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191482 191482/Asset/a1054.jpg | HP N/A 2 | RPM 60 Hz N/A 3600 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 10.8 | NEMA Frame N/A 145TC | C Dimension N/A 14.20 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |
191483 191483/Asset/a1054.jpg | HP N/A 2 | RPM 60 Hz N/A 1800 | Voltage N/A 115 V208 V230 V | FL Amps 230 V N/A 9.0 | NEMA Frame N/A 145TC | C Dimension N/A 14.20 in |
Mechanical Features
N/A These motors have an entirely paint free exterior with 300 series stainless steel motor body, conduit box lid, shaft extension, hardware, fasteners and an etched motor data plate. To enhance chemical and corrosion resistance, all surfaces of the end bells and conduit box are processed using a U.S. Department of Agriculture approved technique. This proprietary process has been tested and qualified for more than 2,500 hours of salt spray endurance for external surfaces, and 1,000 hours for internal surfaces. This process has proven successful in food wash down applications and has shown excellent corrosion resistance. Shaft seals, slingers and one-way stainless steel drains retard entrance of contaminants and water into the motor. Multiple, repositional drains provided for all angle mounting, release any water that does enter the motor from hose downs or condensation. Chemically resistant, tough nitrile gaskets and a threaded entrance for power connection also restrict entrance to the motor’s interior. Nylon gaskets are used to seal bolt heads. Bearings used are double sealed and prelubricated with moisture resistant Exxon POLYREX® EM high temperature lubricant. |
Electrical Features N/A Efficiencies meet EPACT mandates for covered motors when tested without shaft seals. High temperature, moisture resistant IRIS insulation system assures long life on inverter service. Windings are immersed and cured in polyester insulating compound. |
Add To Cart
Request Quote |