Leeson Cast Iron Three Phase Totally Enclosed Fan Cooled (TEFC) Motors
Leeson Miscellaneous
But that's only part of the story. LEESON 150 and 170-series cast iron motors are extremely versatile and can be field converted in minutes to a number of different configurations, including:Severe Duty TEFC (using cast iron fan guard kit) F2 mounting (by reassembly) C face with rigid base (from stock or using C face kit) D flange with base (using D flange kit)
CSA certified under report number LR62104
CSA Energy Efficiency Verification report number EEV78720-1
UL recognized insulation system, file number E55555 and UL recognized construction, file number E57948 on all cast iron motors produced in June 2003 and later.
LEESON’s Inverter Rated Insulation System (IRIS™) provides superior motor protection against voltage spikes induced by variable frequency drives. This total insulation system protects better than spike-resistant magnet wire alone. Specially formed phase insulation, cushioned and sleeved connections (from the leads all the way into the turns), and deep-penetrating, non-hygroscopic, high temperature varnish are just a few features contributing to the extra protection. All this plus second generation, spike-resistant magnet wire. The IRIS™ total insulation system is standard at no extra cost in all LEESON stock NEMA three-phase motors, 1 HP and larger.
Note 150 and 170 Series Drip-Proof and TEFC motors in NEMA frames 180T thru 447T can be field converted, by reassembly, to F2 conduit box locations.
- 150 & 170 Series
- Rigid Base
- General Purpose
But that's only part of the story. LEESON 150 and 170-series cast iron motors are extremely versatile and can be field converted in minutes to a number of different configurations, including:
CSA certified under report number LR62104
CSA Energy Efficiency Verification report number EEV78720-1
UL recognized insulation system, file number E55555 and UL recognized construction, file number E57948 on all cast iron motors produced in June 2003 and later.
LEESON’s Inverter Rated Insulation System (IRIS™) provides superior motor protection against voltage spikes induced by variable frequency drives. This total insulation system protects better than spike-resistant magnet wire alone. Specially formed phase insulation, cushioned and sleeved connections (from the leads all the way into the turns), and deep-penetrating, non-hygroscopic, high temperature varnish are just a few features contributing to the extra protection. All this plus second generation, spike-resistant magnet wire. The IRIS™ total insulation system is standard at no extra cost in all LEESON stock NEMA three-phase motors, 1 HP and larger.
Note 150 and 170 Series Drip-Proof and TEFC motors in NEMA frames 180T thru 447T can be field converted, by reassembly, to F2 conduit box locations.
Item # |
HP |
RPM 60 Hz |
Voltage |
FL Amps 230 V |
NEMA Frame |
C Dimension |
Quantity | Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|---|
171315 | HP N/A 150 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 185.5 | NEMA Frame N/A 445T | C Dimension N/A 48.00 in | Request Quote | |
170260 | HP N/A 125 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 155.0 | NEMA Frame N/A 445T | C Dimension N/A 44.88 in | Request Quote | |
G151368 | HP N/A 125 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 134 | NEMA Frame N/A 444TS | C Dimension N/A 39.10 in | Request Quote | |
170256 | HP N/A 100 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 121 | NEMA Frame N/A 444T | C Dimension N/A 42.87 in | Request Quote | |
170160 | HP N/A 100 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 218 | NEMA Frame N/A 405TS | C Dimension N/A 34.92 in | Request Quote | |
G150160 | HP N/A 100 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 220 | NEMA Frame N/A 405TS | C Dimension N/A 34.92 in | Request Quote | |
170045 | HP N/A 75 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 169 | NEMA Frame N/A 365TS | C Dimension N/A 31.50 in | Request Quote | |
G150045 | HP N/A 75 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 172 | NEMA Frame N/A 365TS | C Dimension N/A 31.50 in | Request Quote | |
170043 | HP N/A 60 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 136 | NEMA Frame N/A 364TS | C Dimension N/A 30.51 in | Request Quote | |
G150043 | HP N/A 60 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 137.0 | NEMA Frame N/A 364TS | C Dimension N/A 30.51 in | Request Quote | |
170041 | HP N/A 50 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 111 | NEMA Frame N/A 326TS | C Dimension N/A 29.53 in | Request Quote | |
G150041 | HP N/A 50 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 112 | NEMA Frame N/A 326TS | C Dimension N/A 29.53 in | Request Quote | |
170039 | HP N/A 40 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 89 | NEMA Frame N/A 324TS | C Dimension N/A 28.03 in | Request Quote | |
G150039 | HP N/A 40 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 93.0 | NEMA Frame N/A 324TS | C Dimension N/A 28.03 in | Request Quote | |
170037 | HP N/A 30 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 67.6 | NEMA Frame N/A 286TS | C Dimension N/A 26.46 in | Request Quote | |
G150037 | HP N/A 30 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 69.2 | NEMA Frame N/A 286TS | C Dimension N/A 26.46 in | Request Quote | |
170035 | HP N/A 25 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 56.8 | NEMA Frame N/A 284TS | C Dimension N/A 24.88 in | Request Quote | |
G150035 | HP N/A 25 | RPM 60 Hz N/A 3550 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 58.2 | NEMA Frame N/A 284TS | C Dimension N/A 24.88 in | Request Quote | |
170033 | HP N/A 20 | RPM 60 Hz N/A 3525 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 46.0 | NEMA Frame N/A 256T | C Dimension N/A 24.92 in | Request Quote | |
G150033 | HP N/A 20 | RPM 60 Hz N/A 3525 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 46.2 | NEMA Frame N/A 256T | C Dimension N/A 24.92 in | Request Quote | |
170062 | HP N/A 15 | RPM 60 Hz N/A 3525 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 35.0 | NEMA Frame N/A 254T | C Dimension N/A 23.19 in | Request Quote | |
G150062 | HP N/A 15 | RPM 60 Hz N/A 3525 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 35.0 | NEMA Frame N/A 254T | C Dimension N/A 23.19 in | Request Quote | |
G151317 | HP N/A 15 | RPM 60 Hz N/A 3510 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 35.0 | NEMA Frame N/A 215T | C Dimension N/A 19.61 in | Request Quote | |
170159 | HP N/A 10 | RPM 60 Hz N/A 3510 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 23.4 | NEMA Frame N/A 215T | C Dimension N/A 19.61 in | Request Quote | |
G150159 | HP N/A 10 | RPM 60 Hz N/A 3510 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 23.6 | NEMA Frame N/A 215T | C Dimension N/A 19.61 in | Request Quote |