1000 HP, 460 V
Unit of Measure

Specifications

Voltage

N/A 460 V

Phase

N/A Three

Frequency

N/A 50/60 Hz

HP (Heavy Duty Rating)

N/A 1000

kW (Heavy Duty Rating)

N/A 710

Rated Output Amps (Heavy Duty Rating)

N/A 1160

Overload Amps (1 Min) (Heavy Duty Rating)

N/A 1740

HP (Light Duty Rating)

N/A 1200

kW (Light Duty Rating)

N/A 800

Rated Output Amps (Light Duty Rating)

N/A 1380

Overload Amps (1 Min) (Light Duty Rating)

N/A 1518

Standard Unit Includes

N/A IP21/NEMA 1 (1) RFI: A2 Keypad Conformal Coated

Factory Installed Keypad

N/A Keypad

Drive Type

N/A IP21/Type 1

A1/B RFI Filter

N/A No A1/B RFI Filter Installed

Brake Chopper

N/A No Factory Installed Brake Chopper

Conformal Coating

N/A Conformal Coatings

Revision

N/A 1st Revision

Options and Accessories

N/A OPC24VPS, 24V DC External Supply Module ($240.00)
OPC4XPED, Pedestal Kit ($875.00)
OPCCOVER4142, Power Shield for Unit Size 41 and 42 Drive ($520.00)
OPCCOVER51, Power Shield for Unit Size 51 Drive ($1,305.00)
OPCDEV, DeviceNet Communications Module ($600.00)
OPCEIP, Ethernet IP Communications Module ($700.00)
OPCENC, Encoder Input Module ($400.00)
OPCGPIO, General Purpose I/O Module ($475.00)
OPCMBTCP, Modbus TCP Communications Module ($700.00)
OPCPDP, Profibus DP Communications Module ($725.00)
OPCPRT, ProfiNet RT Communications Module ($700.00)
OPCRES, Resolver Input Module ($400.00)
OPCRLY, Relay Output Module ($475.00)
OPCRMKNC, Remote Mounting Kit without cable ($85.00)
OPCSAFE, Safe PLC I/O Module ($450.00)
OPCTERM, Screw Terminal Accessory ($25.00)
OPCUSB, USB Kit for All Drives up to Unit Size 5X ($75.00)
OPCUSB6X, USB Kit for All Unit Size 6X drive ($225.00)
RMKYPDAC, Remote Mounting Kit for Graphical LCD Keypad ($95.00)

Environmental Conditions

Enclosure

N/A IP00 Chassis IP20 Chassis IP21/NEMA 1 IP54/NEMA 12 IP55/NEMA 12 IP66/NEMA 4

Installation Location

N/A Do not install in locations where product could be exposed to dust, corrosive gas, inflammable gas, oil mist, vapor, water drops or direct sunlight. There must be no salt in the atmosphere. Condensation must not be caused by sudden changes in temperature. For use at altitudes of 3280 ft. (1000M) or less without derating.

Storage Temperature

N/A -25 to 65 ºC

Ambient Temperature

N/A -10º to +50 ºC (24 hour average max of 45 ºC)

Ambient Humidity

N/A 5 to 95 % RH (non-condensing)

Vibration

N/A 1.0 g

Cooling Method

N/A Fan Cooled all ratings. Fan Control Auto, 50% level, 75% level, 100% level adjustable

Standards

Approvals

N/A CE, UL, cUL, and C-Tick
Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes for 230V and 460V.

Input Power Supply

Rated Input AC Voltage

N/A 200-240 Vac, 3-phase, 50-60 Hz, ± 10 % V 380-500 Vac, 3-phase, 50-60 Hz, ± 10 % V 525-600 Vac, 3-phase, 50-60 Hz, ± 10 % V 525-690 Vac, 3-phase, 50-60 Hz, ± 10 % V

Max. Voltage Imbalance

N/A 3 % of rated supply voltage

True Power Factor

N/A > 0.9 nominal at rated load

Displacement Power Factor

N/A > 0.98

Switching on Input Power Supply

N/A Maximum twice/minute up to 10 HP, Maximum once/minute above 10 HP

Environment According to EN60664-1

N/A Overvoltage category III/pollution degree 2

Output

Rated Output Voltage

N/A 0-100 % of supply voltage

Output Frequency

N/A 0-1000 Hz; 0-800 Hz for 460 V above 100 HP and 525/600/690 V above 100 HP

Switching on Output

N/A Unlimited

Accel/Decel Times

N/A 0.01 to 3600 s

Control Method

N/A Sinusoidal PWM Control (V/Hz, Avd. Vector Control, Sensorless Vector, and Flux Vector with motor feedback)

Control

Starting Torque

N/A 160 % starting torque for 1 minute (constant torque).
110 % starting torque for 1 minute (variable torque)

Carrier Frequency (Motor Noise)

N/A 1 kHz1.5 kHz2 kHz2.5 kHz3 kHz3.5 kHz4 kHz5 kHz6 kHz7 kHz8 kHz10 kHz12 kHz14 kHz16 kHz

Torque Boost

N/A Selectable by up to 5 individual V/Hz settings in V/Hz Mode or by 0 - 300% setting of Torque Boost parameter in Adv. Vector Mode

Acceleration/Deceleration Time

N/A 0.01-3600 seconds (4 acceleration and deceleration times are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or S-curve)

Data Protection

N/A Password Protection for Quick Menu or Main Menu, 0-9999.

Pattern Operation

N/A Settings via Built-In Logic Controller Sequencer

Jump Frequency Control

N/A 4 jump (or skip) frequencies via parameter set to avoid mechanical vibration

Slip Compensation

N/A Maintains motor at constant speed with load fluctuations

Torque Limit Control

N/A Output torque can be controlled within a range of 0.0 to 160 % (0.1 and steps)

8 Preset Speeds

N/A 8 programmable preset speeds selectable by 3 digital inputs

Trim Reference Setting

N/A Available for speed reference offset via potentiometer, voltage input, or current input

DC Injection Braking

N/A Starting frequency: 0.0-1000 Hz, 0-800 Hz for 460 V above 100 HP and 525-690 V above 50 HP
Braking time: 0.0-60.0 seconds
Braking level: 0-100 % of rated current

Jogging Operation

N/A Operation via On key or digital input (Fwd or Rev)

Auto-Restart After Power Failure

N/A Restarts the drive without stopping after instantaneous power failure

Energy Savings

N/A Controls output voltage to minimize motor loss during constant speed operation

Start Mode Function

N/A This functionality smoothly catches a spinning motor

Logic Controller (LC) Sequencer

Logic Controller Events

N/A Up to 37 types of Programmable Events

Comparators

N/A Array of 6 Comparators

Timers

N/A Array of 8 Timers, adjustable from 0.0 to 3600 sec

Logic Rules

N/A Array of 6 Boolean Logic Rules

Logic Controller States

N/A Array of 20 Logic Controller Action States

Process Controller (PID)

Process CL Feedback Select

N/A Encoder Option Module Motor Feedback No function Resolver Option Module Separate Encoder

Process PID Control

N/A Inverse Normal

Process PID Anti Windup

N/A Disabled Enabled

Process PID Start Speed

N/A 0.0 to 200 Hz

Process PID Proportional Gain

N/A 0.00 to 10.00

Process PID Integral Time

N/A 0.1 to 10000.0 ms

Process PID Differential Time

N/A 0.0 to 10 s

Process PID Differential Gain

N/A 1.0 to 50.00

Process PID Feed Forward Factor

N/A 0 to 500 %

On Reference Bandwidth

N/A 0 to 200 %

Operation

Operation Method

N/A Keypad operation: Hand, Off, Auto
Digital Input: Programmable for Start/Stop, Forward/Reverse, Jog
Timer operation: Stop after predetermined time frame Built-in RS-485 Modbus RTU USB Port for programming drive with optional PC Software

Frequency Reference Signal

N/A Left or Right Arrow buttons on keypad in Manual Mode
Speed Potentiometer: 0 to +10 Vdc, 10 to 0 Vdc
0-10 Vdc analog input
0/4-20 ma analog input

References

N/A Up to 3 Input References can be selected from Analog
Input #1 or #2, Frequency Input #1 or #2, Network, or Potentiometer

Input Signals

N/A 6 - Digital Inputs, 24 Vdc PNP or NPN
1 - Safe Stop Digital Input suitable for category 3 installations to meet EN-954-1
2 - Pulse Inputs rated to 110kHz or 1 - Pulse Input and 1 - Encoder Input 24 Vdc rated to 4096 PPR
2 - Analog Inputs -10 to +10V scalable or 0/4 to 20 mA scalable
Digital Input Settings:
No Operation
Reset after drive trip or alarm
Drive at stop with no holding current
Quick Stop according to Quick Stop Decel Time 1
Stop on input going low
Start
Maintained Start after signal applied for Minimum of 2ms
Reversing
Start Reverse
Enable Start Forward only
Enable Start Reverse only
Jog
Multi-Step Frequency selection (1 to 8 Steps)
Hold Drive Frequency
Hold Reference
Speed Up; activated by Hold Drive Frequency or Hold Reference
Slow Down; activated by Hold Drive Frequency or Hold Reference
Drive Parameter Setup Select 1-4
Precise Start or Stop; Activated when drive parameter precise start or stop function is selected Catch Up or Slow Down; Activated by signal to add to or subtract from input reference to control speed
Pulse Input selectable from 100 - 110000Hz
Accel / Decel Time select. Set Input to Accel / Decel Times 1 to 4
Digital Potentiometer Input Increase or Decrease
Mechanical Brake Feedback

Output Signals

N/A 2 - Digital Outputs 24 Vdc (Digital Outputs are used in place of 2 of the Digital Inputs)
2 - Form C Relays rated to 2A at 240 Vac
1 - Analog Output 0/4 to 20mA
Relay Output Settings:
No Operation
Control Ready
Drive Ready
Drive Ready in Remote
Standby No Drive Warnings
Drive Running
Drive Running No Drive Warnings
Drive Running on Remote
Alarm
Alarm or Warning
At Torque Limit
Out of Current Range
Below Current
Above Current
Out of Speed Range
Below Speed
Above Speed
Out of Feedback Range
Below Feedback
Above Feedback
Thermal Overload Warning
Reverse
Bus OK
Torque Limit and Stopped
Brake and no Warning
Brake Ready and No Faults
Rake Chopper Fault
External Interlock
Out of External Reference Range
Below External Reference
Above External Reference
Fieldbus Controlling Drive
No Alarm
Running in Reverse
Local Mode Active
Remote Mode Active
Start Command Active
Hand Mode Active
Auto Mode Active

Protective Functions

N/A Line Phase Loss
DC Over voltage
DC Under voltage
Drive Overload
Motor Over temperature
Motor Thermistor Over temperature
Torque Limit
Overcurrent
Ground Fault
Short Circuit
Control Word Timeout
Brake Resistor Short-Circuited
Brake Chopper Short-Circuited
Brake Check
DC Link Voltage High
DC Link Voltage Low
Internal Fan Fault
External Fan Fault
Power Board Over temperature
Missing U Phase
Missing V Phase
Missing W Phase
Internal Fault
Control Voltage Fault
Auto Tune Check - Wrong Motor Parameters
Auto Tune Low Inom - Motor current is too low
Current Limit
Mechanical Brake Low
Drive Initialized to Default Value
Keypad Error
No Motor
Soft Charge Fault
Auto Tuning Fault
Serial Comms Bus Fault
Hardware Mismatch
Speed Limit

Keypad

Keypad Features

N/A LCD Display with 6 Alpha-numeric lines. Multi-Language Support
Hot Pluggable, Remote Mount Option, and CopyCat Feature, IP65 rating when remote mounted on enclosure
LED's - Green - drive is on, Yellow - indicates a warning, Red - indicates an alarm, Amber - Indicates active Menu keys and H-O-A keys

Keypad Keys

N/A Status - shows status of drive
Quick Menu - Enters Quick Start, Parameter Data Check, or Trending Modes
Main Menu - Used for programming all drive parameters
Alarm Log - Used to display Alarm list
Back - Reverts to previous step or layer in parameter structure
Cancel - Used to cancel last change or command
Info - Displays information about a command, parameter, or function in any display.
Hand/Off/Auto - Used to control drive locally or put drive in remote mode
Reset - Used to reset Warnings or Alarms

Password

N/A 2 Level Password Protection

Alternate Motor Parameters

N/A Up to 4 Separate complete parameter set-ups are available

Graphical Trending

N/A Trend Speed, Power, Frequency or any value programmed in status display

RS485 Modbus RTU Serial Communications

Physical Level

N/A EIA/RS485

Transmission Distance

N/A 1640 ft500 m

Node Address

N/A 32

Transmission Speed

N/A 2400 bits/s4800 bits/s9600 bits/s19200 bits/s38400 bits/s115200 bits/s

Transmission Mode

N/A Half Duplex

Transmission Protocol

N/A Modbus RTU

Character Code

N/A Binary

Character Length

N/A 8 bits

Error Check

N/A CRC

Mounting Clearance

N/A All AF-650 GP drives can be mounted Side-by-Side without spacing.
For all drives rated 100HP or below allow 3.4 inches
(100 mm) free space above and below.
For all drives rated 125 HP and above allow 8.9 inches (225 mm) free space above and below.