Leeson Cast Iron Three Phase Totally Enclosed Fan Cooled (TEFC) Motors
General Purpose TEFC Motors
But that's only part of the story. LEESON 150 and 170-series cast iron motors are extremely versatile and can be field converted in minutes to a number of different configurations, including:Severe Duty TEFC (using cast iron fan guard kit) F2 mounting (by reassembly) C face with rigid base (from stock or using C face kit) D flange with base (using D flange kit)
CSA certified under report number LR62104
CSA Energy Efficiency Verification report number EEV78720-1
UL recognized insulation system, file number E55555 and UL recognized construction, file number E57948 on all cast iron motors produced in June 2003 and later.
LEESON’s Inverter Rated Insulation System (IRIS™) provides superior motor protection against voltage spikes induced by variable frequency drives. This total insulation system protects better than spike-resistant magnet wire alone. Specially formed phase insulation, cushioned and sleeved connections (from the leads all the way into the turns), and deep-penetrating, non-hygroscopic, high temperature varnish are just a few features contributing to the extra protection. All this plus second generation, spike-resistant magnet wire. The IRIS™ total insulation system is standard at no extra cost in all LEESON stock NEMA three-phase motors, 1 HP and larger.
Note 150 and 170 Series Drip-Proof and TEFC motors in NEMA frames 180T thru 447T can be field converted, by reassembly, to F2 conduit box locations.
- 150 & 170 Series
- Rigid Base
- General Purpose
But that's only part of the story. LEESON 150 and 170-series cast iron motors are extremely versatile and can be field converted in minutes to a number of different configurations, including:
CSA certified under report number LR62104
CSA Energy Efficiency Verification report number EEV78720-1
UL recognized insulation system, file number E55555 and UL recognized construction, file number E57948 on all cast iron motors produced in June 2003 and later.
LEESON’s Inverter Rated Insulation System (IRIS™) provides superior motor protection against voltage spikes induced by variable frequency drives. This total insulation system protects better than spike-resistant magnet wire alone. Specially formed phase insulation, cushioned and sleeved connections (from the leads all the way into the turns), and deep-penetrating, non-hygroscopic, high temperature varnish are just a few features contributing to the extra protection. All this plus second generation, spike-resistant magnet wire. The IRIS™ total insulation system is standard at no extra cost in all LEESON stock NEMA three-phase motors, 1 HP and larger.
Note 150 and 170 Series Drip-Proof and TEFC motors in NEMA frames 180T thru 447T can be field converted, by reassembly, to F2 conduit box locations.
Item # |
HP |
RPM 60 Hz |
Voltage |
FL Amps 230 V |
NEMA Frame |
C Dimension |
Quantity | Add To Cart/Request Quote |
---|---|---|---|---|---|---|---|---|
170045 | HP N/A 75 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 169 | NEMA Frame N/A 365TS | C Dimension N/A 31.50 in | Request Quote | |
170062 | HP N/A 15 | RPM 60 Hz N/A 3525 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 35.0 | NEMA Frame N/A 254T | C Dimension N/A 23.19 in | Request Quote | |
170066 | HP N/A 15 | RPM 60 Hz N/A 1770 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 36 | NEMA Frame N/A 254T | C Dimension N/A 23.19 in | Request Quote | |
170068 | HP N/A 15 | RPM 60 Hz N/A 1170 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 40.6 | NEMA Frame N/A 284T | C Dimension N/A 26.26 in | Request Quote | |
170087 | HP N/A 100 | RPM 60 Hz N/A 1780 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 225.0 | NEMA Frame N/A 405T | C Dimension N/A 37.91 in | Request Quote | |
170096 | HP N/A 40 | RPM 60 Hz N/A 1180 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 102.0 | NEMA Frame N/A 364T | C Dimension N/A 32.64 in | Request Quote | |
170097 | HP N/A 50 | RPM 60 Hz N/A 1180 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 124.0 | NEMA Frame N/A 365T | C Dimension N/A 33.62 in | Request Quote | |
170098 | HP N/A 60 | RPM 60 Hz N/A 1190 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 142 | NEMA Frame N/A 404T | C Dimension N/A 36.42 in | Request Quote | |
170099 | HP N/A 75 | RPM 60 Hz N/A 1190 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 176 | NEMA Frame N/A 405T | C Dimension N/A 37.91 in | Request Quote | |
170123 | HP N/A 10 | RPM 60 Hz N/A 1170 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 29 | NEMA Frame N/A 256T | C Dimension N/A 24.92 in | Request Quote | |
170140 | HP N/A 10 | RPM 60 Hz N/A 1760 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 25.0 | NEMA Frame N/A 215T | C Dimension N/A 19.61 in | Request Quote | |
170159 | HP N/A 10 | RPM 60 Hz N/A 3510 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 23.4 | NEMA Frame N/A 215T | C Dimension N/A 19.61 in | Request Quote | |
170160 | HP N/A 100 | RPM 60 Hz N/A 3570 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 218 | NEMA Frame N/A 405TS | C Dimension N/A 34.92 in | Request Quote | |
170256 | HP N/A 100 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 121 | NEMA Frame N/A 444T | C Dimension N/A 42.87 in | Request Quote | |
170260 | HP N/A 125 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 155.0 | NEMA Frame N/A 445T | C Dimension N/A 44.88 in | Request Quote | |
170352 | HP N/A 200 | RPM 60 Hz N/A 1790 | Voltage N/A 460 V | FL Amps 230 V N/A 216 | NEMA Frame N/A 447T | C Dimension N/A 48.00 in | Request Quote | |
170369 | HP N/A 125 | RPM 60 Hz N/A 1190 | Voltage N/A 460 V | FL Amps 230 V N/A 137.5 | NEMA Frame N/A 444T | C Dimension N/A 42.87 in | Request Quote | |
170371 | HP N/A 150 | RPM 60 Hz N/A 1190 | Voltage N/A 460 V | FL Amps 230 V N/A 163.0 | NEMA Frame N/A 445T | C Dimension N/A 44.88 in | Request Quote | |
171315 | HP N/A 150 | RPM 60 Hz N/A 3570 | Voltage N/A 460 V | FL Amps 230 V N/A 185.5 | NEMA Frame N/A 445T | C Dimension N/A 48.00 in | Request Quote | |
171316 | HP N/A 200 | RPM 60 Hz N/A 1770 | Voltage N/A 460 V | FL Amps 230 V N/A 241.5 | NEMA Frame N/A 449T | C Dimension N/A 52.80 in | Request Quote | |
171578 | HP N/A 150 | RPM 60 Hz N/A 1790 | Voltage N/A 460 V | FL Amps 230 V N/A 161 | NEMA Frame N/A 445TS | C Dimension N/A 44.88 in | Request Quote | |
171579 | HP N/A 200 | RPM 60 Hz N/A 1785 | Voltage N/A 460 V | FL Amps 230 V N/A 216.5 | NEMA Frame N/A 447TS | C Dimension N/A 48.00 in | Request Quote | |
171580 | HP N/A 125 | RPM 60 Hz N/A 1780 | Voltage N/A 460 V | FL Amps 230 V N/A 132 | NEMA Frame N/A 444TS | C Dimension N/A 39.10 in | Request Quote | |
G140489 | HP N/A 10 | RPM 60 Hz N/A 1740 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 26 | NEMA Frame N/A 215T | C Dimension N/A 18.71 in | Request Quote | |
G140686 | HP N/A 10 | RPM 60 Hz N/A 3450 | Voltage N/A 208 V230 V460 V | FL Amps 230 V N/A 24.0 | NEMA Frame N/A 215T | C Dimension N/A 19.84 in | Request Quote |